Option 23: 300 Baud

When 300 Baud is set to ON, a 300 bps modem connection is established
from the panel to the central monitoring station; when the option is set to
OFF, a 110 bps connection is established.

Option 24: AVM Enable

When the AVM Enable option is set to ON, the panel to conducts a two-way
audio session with a central monitoring station operator.
Note
For Auto Listen Mode (Option 26) to function, AVM Enable must be ON.

Option 25: Trouble Beeps

The Trouble Beeps option controls the number of beeps that sound after the
panel detects a trouble condition. If the option is set to ON, the panel sounds
six beeps each minute; if the option is set to OFF, the panel beeps once.
The following conditions may cause trouble beeps: AC power failure (after
five minutes); low CPU battery; sensor failure; sensor trouble; fail to com-
municate; RF jam.
To silence a trouble beep, press Status. If the condition is not cleared, a
series of trouble beeps sounds again after four hours.
Note
For ETL listed systems, the Trouble Beeps option must be set to ON.

Option 26: Auto Listen Mode

The Auto Listen Mode controls the panel's ability to process audio ses-
sions. When set to ON, the panel hangs up and waits for a monitoring station
operator to call prior to initiating an audio session
If a call-back is not received within five minutes, the panel returns to normal
operating mode. When set to OFF, the panel remains online for an instant
audio session.
Note
For Auto Listen Mode to function properly, AVM Enable (Option 24) must be ON.
If Option 26 is set to ON, do not enable Option 5. The central station operator
cannot connect to the panel while a voice event notification or pager is contacted.

Option 27: RF Jam Detect

The RF Jam Detect option allows the panel to check for and report RF
interference. If the option is set to ON, and the Status button is pressed
while the panel receives a constant 319.5 MHz signal, the panel announces
"RF interference detected" and a report is sent to the central monitoring sta-
tion. If the option is set to OFF, the panel does not detect RF interference.
Note
After initial powering or memory clear, the panel cannot detect an RF Jam for four
hours. For ETL listed systems, the RF Jam Detect option must be set to ON.
15
Range = On/Off (Default = On)
¾
To program 300 Baud:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 3.
4. Press Done.
Range = On/Off (Default = On)
¾
To program AVM Enable:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 4.
4. Press Done.
Range = On/Off (Default = On)
¾
To program Trouble Beeps:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 5.
4. Press Done.
Range = On/Off (Default = Off)
¾
To program Auto Listen Mode:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 6.
4. Press Done.
Range = On/Off (Default = Off)
¾
To program RF Jam Detect:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 7.
4. Press Done.
Programming Options