Low CPU Battery (06004)
When this setting is on, the panel reports a low panel battery to the
central station before shutting down.
Note
For UL 1635 listed installations, this feature must be set to on.
Battery Restoral (06005)
If this setting is on, the panel reports to the central monitoring sta-
tion when a wireless sensor or touchpad reports a battery replace-
ment to the panel.
Buffer Full Rpt (06006)
When this setting is on, the panel sends an "event buffer full"
report to the central monitoring station when the event buffer is
nearly full.
Zone Restorals (06007)
When this setting is on, the panel reports a restoral to the central
monitoring station for wireless or hardwire zones in alarm before
the alarm is canceled.
Note
As with all GE Security panels, hardwire smoke detectors connected to
Concord Ultra or SnapCard hardwire zones do not send restorals.
Two Trip Error (06008)
This setting works with the Alarm Verify setting (see "Alarm Ver-
ify" later in this section and Appendix B: Table B1 "Sensor Table
Characteristics"). If Alarm Verify is on, then the panel waits for a
second sensor trip before sending an alarm.
Note
For UL Listed installations, this feature must be set to off.
If Two Trip Error is also on and a second sensor trip does not occur
within a 4-minute time period, then the panel sends an error report
to the central monitoring station.
41
Reporting-Global (Default = on)
¾
To turn Low CPU Battery reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Battery Restoral reports off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
ON
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Buffer Full Report off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Zone Restoral reporting off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
Reporting-Global (Default = off)
¾
To turn Two Trip Error off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
LOW CPU BATTERY OFF/ON
BATTERY RESTORAL OFF/
BUFFER FULL RPT OFF/ON
ZONE RESTORALS OFF/ON
TWO TRIP ERROR OFF/ON