Upgrading Pse Processing Software Online; Configuring A Pd Disconnection Detection Mode - 3Com 4210G Series Configuration Manual

24-port/48-port
Hide thumbs Also See for 4210G Series:
Table of Contents

Advertisement

When the current power utilization of the PSE is above or below the alarm threshold for the first
time, the system will send a Trap message.
When the PSE starts or stops supplying power to a PD, the system will send a Trap message, too.
Configuring a Power Alarm Threshold for the PSE
To do...
Enter system view
Configure a power alarm
threshold for the PSE

Upgrading PSE Processing Software Online

You can upgrade the PSE processing software online in either of the following two modes:
refresh mode
This mode enables you to update the PSE processing software without deleting it.
full mode
This mode deletes the PSE processing software and reloads it. When the PSE processing software is
damaged (in this case, you can execute none of PoE commands successfully), you can upgrade the
PSE software processing software in full mode to restore the PSE function.
Online PSE processing software upgrade may be unexpectedly interrupted (for example, an error
results in device reboot). If you fail to upgrade the PSE processing software in full mode after reboot,
you can power off the device and restart it before upgrading it again. After upgrade, restart the device
manually to make the original PoE configurations take effect.
Follow these steps to upgrade the PSE processing software online:
To do...
Enter system view
Upgrade the PSE processing
software online

Configuring a PD Disconnection Detection Mode

To detect the PD connection with PSE, PoE provides two detection modes: AC detection and DC
detection. The AC detection mode is energy saving relative to the DC detection mode.
Follow these steps to configure a PD disconnection detection mode:
To do...
Enter system view
Configure a PD
disconnection detection
mode
Use the command...
system-view
poe utilization-threshold
utilization-threshold-value pse pse-id
Use the command...
system-view
poe update { full | refresh }
filename pse pse-id
Use the command...
system-view
poe disconnect { ac | dc }
29-6
Remarks
Optional
80% by default.
Remarks
Optional
Remarks
Optional
The default PD disconnection
detection mode varies with devices.