Maximum Number of RFID Write Retries

This parameter is to set the maximum number of times to write data onto an RFID tag.
If the printer does not succeed even if after having retried for the maximum number of times, the printer
stops, resulting in an error (RFID WRITE ERROR). In case of frequent write errors, increase this retry
count. However, when the retry count is increased, writing data may become slower.
If the specified time-out runs out, the printer stops retry even before the maximum number of retry times is
reached.
When "W CYCLE CNT 5" is displayed, press the [PAUSE] key.
<10>RFID
W CYCLE CNT
Use the [FEED] or [RESTART] key to select a desired option. (Range: 0 to 255)
[RESTART]
[FEED]
[FEED] key:
[RESTART] key: Pressing the [RESTART] key one time causes a +1 change, up to 255.
After selecting the maximum number of write retries, press the [PAUSE] key.
5
W CYCLE CNT 255
W CYCLE CNT
3
W CYCLE CNT
2
W CYCLE CNT
1
W CYCLE CNT
0
Pressing the [FEED] key one time causes a –1 change, up to 0.