When the RFID module type is set to "NONE" or a communication cannot be established, a
message, "NON RFID MODULE", is displayed.
"NO RFID MODULE", "TIMEOUT" or "RFID READ ERROR" indicates an error. In that case, check
the following:
• In case of NO RFID MODULE
- Connection failure of the antenna cable ⇒ Check the connection.
- Connection failure of the interface cable ⇒ Check the connection.
- Wrong parameter setting ⇒ Check the parameter setting.
• In case of TIMEOUT or RFID READ ERROR
- The RFID tag used is hard to read. ⇒ Refer to the Product Description and check the available
RFID tag types.
- TOSHIBA-recommended tag is not used. ⇒ Refer to the Product Description and check the
available RFID tag types. Increase the value for R CYCLE CNT or R CYCLE TIM
3)
In case a test succeeded, a read test will be performed each time the [PAUSE] key is pressed.
4)
To finish a read test, turn off the printer.
2.9.2

RFID Module Type Selection

This parameter is to choose an RFID module type to be used. Improper choice will disable the RFID
module. The initial setting (including the status after a parameter clear) is "MODULE NONE".
When "MODULE NONE" is displayed, press the [PAUSE] key.
<10>RFID
MODULE NONE
Use the [FEED] or [RESTART] key to select a desired option.
[RESTART]
[FEED]
NOTE: This parameter setting is effective when turning OFF then ON the printer.
After selecting the RFID module type to be used, press the [PAUSE] key.
MODULE NONE
MODULE
U2
RFID module is not used. (default)
B-SX708-RFID-U2-EU-R or B-SX708-RFID-U2-CN-R is
installed.
2-75
EO13-33002
(Revision Date: Mar. 26, 2009)
2.9 RFID Module Setting