Lin Triggering - Agilent Technologies 7000B Series User Manual

7000b series
Hide thumbs Also See for 7000B Series:
Table of Contents

Advertisement

10
CAN/LIN Triggering and Serial Decode

LIN Triggering

To set up the oscilloscope to capture a LIN signal, see
Signals"
LIN triggering will trigger on the rising edge at the Sync Break exit of the
LIN single- wire bus signal that marks the beginning of the message frame.
If the N5424A CAN/LIN Automotive Triggering and Decode option is
installed on your oscilloscope, the Frame ID and Frame ID and Data
trigger types are also available.
A LIN signal message frame is shown below:
1 Press [Trigger]; then, select the LIN trigger type.
2 Repeatedly press and release the Trigger: softkey or rotate the Entry
3 Press the Trigger: softkey and choose the type of trigger:
274
on page 272.
Sync
Sync
Field
Break
Sync Break Exit
knob to select the trigger condition.
Sync (Sync Break) — The oscilloscope triggers on the rising edge at
the Sync Break exit of the LIN single- wire bus signal that marks the
beginning the message frame.
ID (Frame ID) — The oscilloscope triggers when a frame with an ID
equal to the selected value is detected. Use the Entry knob to select
the value for the Frame ID.
ID & Data (Frame ID and Data) — The oscilloscope triggers when a
frame with an ID and data equal to the selected values is detected.
When triggering on a frame ID and data:
To select the frame ID value, press the Frame ID softkey, and use
the Entry knob.
Identifier
Data
Fields
Break
InfiniiVision 7000B Series Oscilloscopes User's Guide
"Setup for LIN
Checksum
Field

Advertisement

Table of Contents
loading