Toshiba B-EX4T1 Series Owner's Manual page 82

Hide thumbs Also See for B-EX4T1 Series:
Table of Contents

Advertisement

2.PRINTER SETUP
2.10 Threshold Setting
(Cont.)
NOTE:
To make a threshold value set
in this section effective, select
the Transmissive Sensor (when
using pre-printed media) or
Reflective Sensor (when using
manual threshold value) in
Issue Command or the printer
driver.
NOTE:
The threshold can be manually
set as follows:
Manually set threshold =
Peak voltage – Threshold fine
adjustment value
e.g.) When Peak=3.5V and
Fine adjustment value=1.0V,
the threshold will be set to
2.5V.
Display example
1
2
3
4
5
6
(5) Press the [RIGHT] to see the details.
(e.g: Succeeded)
(6) To return to the previous display, press the [LEFT].
To adjust the threshold, press the [RIGHT]. The threshold fine
adjustment screen in ADJUST SET menu appears.
Set a value and press the [ENTER].
(7)
The result after manually setting the threshold is displayed.
E2-68
ENGLISH VERSION EO1-33089
Explanation
Result: OK (Mid.)
Threshold is at the midpoint between the
peak and the baseline.
Result: OK (High)
Threshold is near the peak voltage.
Adjusting the threshold to the midpoint
between the peak and the baseline enables
more accurate detection.
Result: OK (Low)
Threshold is near the baseline voltage.
Adjusting the threshold to the midpoint
between the peak and the baseline enables
more accurate detection.
Failed (1)
The media sensor cannot detect a gap/black
mark. Sensor adjustment is required.
(⇒Section 2.11)
Failed (1)
The media sensor cannot detect a gap/black
mark. (Threshold ≤ Baseline) Sensor
adjustment is required. (⇒Section 2.11)
Failed (2)
Detection by the media sensor is disabled.
Sensor adjustment is required. (⇒Section
2.11)
(e.g.: Failed)
2.10 Threshold Setting
Sensor type
Peak voltage
Threshold voltage
Baseline voltage
Key operation guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents