APPENDIX 1 MESSAGES AND LEDS
NOTES:
• If a command error is found in the command received, up to 42 bytes of the erroneous command, starting from the
command code, will be displayed. (However, [LF] and [NUL] will not be displayed.)
Example 1
[ESC]PC001;0A00,0300,2,2,A,00,B[LF][NUL]
Command error
The following message appears.
SYNTAX ERROR
PC001;0A00,0300,2,2,A
,00,B
Example 2
[ESC]T20G30[LF] [NUL]
Command error
The following message appears.
SYNTAX ERROR
T20G30
Example 3
[ESC]PC002;0100,0300,15,15,A,00,00,J0101,+000000000A,Z10,P1[LF] [NUL]
The following message appears.
SYNTAX ERROR
PC002;0100,0300,15,15
,A,00,00,J0101,+00000
• When the error command is shown, "? (3FH)" appears for codes other than codes 20H to 7FH and A0H to DFH.
• The battery level is not checked when the printer is reset or real time clock is not installed.
• For details, please refer to the B-EX4T/EX6T Series External Equipment Interface Specification.
Command error