Control Unit Power Up - Avaya IP Office Installation Manual

Hide thumbs Also See for IP Office:
Table of Contents

Advertisement

6.3 Control Unit Power Up

This procedure starts a new IP Office control unit not connected to any LAN. In this scenario the IP Office control unit will
assume its default configuration settings.
Objective - To power up the IP Office control unit to a known state with a known set of defaults.
Parts and Equipment Required
1. o Switched power outlet socket.
2. o IP Office Control Unit.
3. o Locale Specific Power Cord.
Procedure
1. Remove the control unit from its box and check its condition. Check that an external power supply unit has been
included with the control unit.
2. Connect the external power supply unit to the control unit.
3. Connect the power cord from the power supply outlet to the external power supply unit.
· Power cords must not be attached to the building surface or run through walls, ceilings, floors and similar openings.
Installation measures must be taken to prevent physical damage to the power supply cord, including proper routing
of the power supply cord and provision of a socket outlet near the fixed equipment or positioning of the equipment
near a socket outlet.
4. Switch on power to the control unit.
5. Observe the center LED on the front of the control unit. Initially this LED will be red. After approximately 10 seconds it
should change to green. During this time other LED's may flash as the unit goes through its power on self test cycle.
IP Office Default Settings
The following are the basic default configuration settings for an IP Office system.
System
LAN*
· Extensions and Users
A user is automatically created for each physical extension port detected in the system. Users are assigned extension
numbers starting from 201. User names take the form Extn201, Extn202, ....
· Hunt Group
A single hunt group 200 called Main is created and the first 10 users are placed into that hunt group as members.
· Incoming Call Routes
Two default incoming call routes are created. Voice calls are routed to the hunt group Main. Data calls are routed to the
RAS user DialIn.
· Default Short Codes
IP400 control units are manufactured as either A-Law or U-Law variants. For IP500 control units, A-Law or U-Law
variant operation is determined by the IP500 Smart Card installed. Depending on the variant, different sets of short
codes are created for the default configuration. Refer to the IP Office Manager application help for full details.
· Default DHCP/Data Settings
When a defaulted IP Office control unit is switched on, it requests IP address information from a DHCP Server on the
network. This operation will occur whether the LAN cable is plugged in or not.
· If a DHCP server responds within approximately 10 seconds, the control unit defaults to being a DHCP client and
uses the IP address information supplied by the DHCP server.
IP Office Installation
IP Office
Name
System Password
License Server IP Address
IP address
IP Mask
DHCP Mode
No of DHCP IP Addresses
*See Default DHCP/Data Settings detail below.
IP400 Basic Installation: Installing the Admin Applications
MAC address of the control unit.
password
255.255.255.255
LAN1
LAN2/WAN
192.168.42.1.
192.168.43.1
255.255.255.0
255.255.255.0
Server
Server
200.
200.
15-601042 Issue 19l (06 November 2008)
Page 97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents