JUKI ASN-690 Instruction Manual page 29

Table of Contents

Advertisement

8 Setting the time for the stacker blow (level 1)
The length of tme durng whch the stacker blow works after the delay tme for the stacker blow has
elapsed.
.
9 Setting the delay time for lifting the thread trimmer (level 2)
The tme to elapsed before lftng the thread trmmer presser after the stacker blow has worked s set.
.
!0 Setting the speed of stitch for the high-speed mode (level 1)
The speed of sttch for the hgh-speed mode s set.
!1 Setting the speed of stitch for the low-speed mode (level 1)
The number of low-speed revolutons s set.
!2 Setting the speed of stitch for the curve sensor (level 1)
The speed of sttch for the secton where the curve sensor s effectve (from the number of sttches at
whch the curve sensor starts to the one at whch the sensor stops) s set.
!3 Setting the speed of stitch for producing chain-off thread (level 2)
The speed of sttch to be employed when operatng the chan-off thread (startng) pedal.
!4 Setting of the start delay time (level 2)
The tme to be elapsed before startng the machne after the materal has been detected s set.
!5 Setting of the number of delay stitches for stopping the machine (level 1)
The number of sttches to be sewn before the machne stops after the normal-seam materal (other than
the stack mode) has come out of the sensor s set.
"sti/min" is an abbreviation for "stitches per minute."
Settng range 0 to 9900 ms
Settng range 0 to 00 ms
Settng range 00 to 8000 st/mn
Settng range 00 to 8000 st/mn
Settng range 00 to 8000 st/mn
Settng range 00 to 8000 st/mn
Settng range 0 to 9900 ms
Settng range 0 to 999 sttches