Replacing The Power Supply Fan Unit; Removing A Chassis Fan Unit - HP Integrity rx1600 Operation And Maintenance Manual

Rsvla-0302
Hide thumbs Also See for Integrity rx1600:
Table of Contents

Advertisement

NOTE

Replacing the Power Supply Fan Unit

To replace a power supply fan unit, perform the following steps:
Step
1. Orient the power supply fan unit by aligning the appropriate icon on the fan unit to the identical icon on the chassis
wall.
Step
2. Push the fan unit firmly into the housing until flush to the top of the chassis.
Step
3. Check the front panel diagnostic LEDs for indication of the replaced fan unit.
When the fan is functioning normally, the LED is off.
When the fan fails, the LED is on.
Step
4. Replace the cover.

Removing a Chassis Fan Unit

To remove a chassis fan unit, perform the following steps:
Step
1. Remove the cover. See "Removing and Replacing the Cover".
Step
2. Grasp the fan unit at the center of the unit and pull the unit up and out of the chassis.
Chapter 7
When one fan unit is removed from the server, the remaining fan units operate at full speed for
two minutes. After two minutes a "soft-shutdown" will occur.
Removing and Replacing Components
Removing and Replacing Fan Units
151