Enter new value, or [Q] to Quit:
Step
6. To decode the blinking state of system LED, review the entire SEL and look at events with alert level 3 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Data1: State Asserted
0x200000000C020570 FFFF010302050300
NOTE
Systems without a Management Processor Card
The system LED states operate the same with systems having the optional management processor card.
Table 6-3
Power and System LED States
Power LED
Off
On (green)
On (green)
On (green)
On (green)
Chapter 6
T - Text mode
Sensor: Cable / Interconnect - SCSI ChExt Cable
Sensor: Physical Security - Chassis Open
More detailed information on the system logs is presented under Chapter 5, "Utilities."
System LED
Off
Solid green
Blinking green
Blinking yellow (1/sec.)
Blinking red (2/sec.)
Identifying and Diagnosing Hardware Problems
Off
Running
Booting or running code other than
operating system (boot or diagnostic).
Attention indication
Fault indication
Troubleshooting
State