Replacing A Chassis Fan Unit; Figure 7-26 Chassis Fan Units Removal/Replacement - HP Integrity rx1600 Operation And Maintenance Manual

Rsvla-0302
Hide thumbs Also See for Integrity rx1600:
Table of Contents

Advertisement

Removing and Replacing Components
Removing and Replacing Fan Units
NOTE
Figure 7-26
Chassis Fan Units Removal/Replacement
Chassis Fan

Replacing a Chassis Fan Unit

To replace a chassis fan unit, perform the following steps:
Step
1. Orient the chassis fan unit by aligning the appropriate icon on the fan unit to the identical icon on the chassis wall.
Step
2. Push the fan unit firmly into the housing until flush to the top of the chassis.
Step
3. Check the front panel diagnostic LEDs for indication of the replaced fan unit.
When the fan is functioning normally, the LED is off.
When the fan fails, the LED is on.
Step
4. Replace the cover.
152
When one fan unit is removed from the server, the remaining fan units operate at full speed for
two minutes. After two minutes a "soft-shutdown" will occur.