HP Guardian Errors Manual page 179

Procedure errors and messages manual
Table of Contents

Advertisement

Recovery Take corrective action as indicated by the error subcode. In many cases, the object file
was improperly built or corrupted. Consider relinking and recompiling the file.
99
ERROR IN PRELOADING A PUBLIC DLL
Cause A failure occurred while attempting to preload a public DLL specified in the zreg file. Error
details are:
nl
1- The export digest of the public DLL is not a match to the export digest found in the specified
zreg file.
nl
2- The license value of the public DLL is not a match to the license value found in the specified zreg
file.
nl
3- The public DLL is licensed and has unprotected data.
nl
4- The public DLL is not preset.
nl
5- The public DLL has a priv or callable Main procedure.
nl
6- The public DLL does not support highpin.
nl
7- The public DLL is not owned by super ID.
nl
8- The public DLL has callable procedures and is not licensed.
nl
9- A public DLL with this name has already been preloaded (duplicate name in zreg).
nl
10- The text, data, or gateway of the public DLL overlaps that of another public DLL.
nl
1 1- The export digest attribute for this public DLL is missing from the zreg file.
Effect The public DLL is not preloaded into the public library table.
Recovery Contact your service provider reporting the error code and error detail if you are using
a zreg file and public DLL set that was created by PLINSTL and has not been modified. If you have
been attempting to adjust the public DLL set manually (not recommended), fix or replace the loadfile
based on the problem reported in the error detail, or run PLINSTL to create an appropriate set of
public DLLs.
104
UNABLE TO CREATE OSS PROCESS
Cause (This error is returned only by PROCESS_SPAWN_.) An OSS process cannot be created
because there are insufficient resources.
Effect No process is created.
Recovery The recovery method depends on the error-detail code received:
Recovery 1: Request TNS floating point in your creation request, or upgrade to a release and
processors that support IEEE floating point.
Recovery 2: Change your process create request to one of the supported floating point types.
Recovery 3: Recompile the object file(s) with the same floating point type for all.
106
OSS START INTERPRETER ERROR
Cause (This error is returned only by PROCESS_SPAWN_.) The oss-program-fileparameter is an
interpreter shell script that cannot be started. The error-detail information contains the error number
of the file-system error that occurred.
Effect No interpreter script file is started.
Recovery Refer to
"File-System Errors" (page
error-detail information.
107
OSS STATIC VARIABLE ERROR
19), for corrective action for the error returned in the
Error Codes 179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Guardian

Table of Contents