Table 6 NEWPROCESS Error 6 Error Subcodes (continued)
Decimal
Octal
Meaning
84
%124
The code area of the program file is too large.
85
%125
The code area of the library file is too large.
86
%126
The program file has a gateway (GW) table but no callable procedures.
87
%127
The library file has a gateway (GW) table but no callable procedures.
89
%131
The file codes of the program file and library file do not match.
90
%132
The program file being started can run only in the Guardian environment and it is being
started in the OSS environment, or vice versa.
91
%133
The library file being started can run only in the Guardian environment and it is being started
in the OSS environment, or vice versa.
92
%134
The program and the library conflict on global data mapping. This error is reported on the
program. The user library selected is not compatible with the user library specified when the
Binder program originally created the program object file.
94
%136
The program needs to import data from the library and the library is not exporting any data.
This error is reported on the program.
96
%140
The program file uses a library and is switching to a new library, but the program was
accelerated by a version of the Accelerator that cannot handle library data relocation at fixup
time.
98
%142
The program file has no code spaces.
99
%143
The library file has no code spaces.
100
%144
The program file is not executable. Either it was not linked with the nld utility, it was not linked
correctly, or it has been corrupted.
101
%145
The library file is not executable. Either it was not linked with the nld utility, it was not linked
correctly, or it has been corrupted.
102
%146
The program file is not executable. Either it was linked with an incompatible version of the
nld utility or it has been corrupted.
103
%147
The library file is not executable. Either it was linked with an incompatible version of the nld
utility or it has been corrupted.
104
%150
The program file is not executable because it has more than one Tandem information header.
An error occurred during the linking of the program file.
105
%151
The library file is not executable because it has more than one Tandem information header.
An error occurred during the linking of the library file.
106
%152
The program file is not executable because it has more than one REGINFO information header.
An error occurred during the linking of the program file.
107
%153
The library file is not executable because it has more than one REGINFO information header.
An error occurred during the linking of the library file.
108
%154
The program file is not executable because it does not have a GINFO information header.
An error occurred during the linking of the program file.
109
%155
The library file is not executable because it does not have a GINFO information header. An
error occurred during the linking of the library file.
1 10
%156
The program file is not executable because it does not have either a Tandem information
header, a REGINFO information header, or a text header. An error occurred during the
linking of the program file.
1 1 1
%157
The library file is not executable because it does not have either a Tandem information header,
a REGINFO information header, or a text header. An error occurred during the linking of the