If the consistency check failed for a TAPE DEFINE, the consistency check number returned indicates
the cause:
Code
Meaning
001
Use RETENTION or EXPIRATION, not both.
002
USE IN and USE EXTEND require LABELS ANSI, LABELS IBM, or LABELS IBMBACKUP. In addition, if REELS
is specified, the value must equal the number of volumes listed for VOLUME.
003
VOLUME is required with LABELS ANSI, LABELS IBM, or LABELS IBMBACKUP.
004
The EBCDIC attribute cannot be used with LABELS ANSI.
005
If RECFORM F is specified, BLOCKLEN must be a multiple of RECLEN.
006
Use DEVICE or SYSTEM, but not both.
007
DEVICE is required for LABELS BYPASS or LABELS OMITTED. The BLOCKLEN, EBCDIC, EXPIRATION, FILEID,
FILESECT, FILESEQ, GEN, OWNER, RECFORM, RECLEN, REELS, RETENTION, SYSTEM, USE, VERSION,
and VOLUME attributes cannot be used with LABELS BYPASS or LABELS OMITTED.
008
VOLUME SCRATCH cannot be specified with USE IN or USE EXTEND.
009
FILEID must be specified with LABELS IBM or LABELS IBMBACKUP.
010
RECLEN must be greater than 0 when BLOCKLEN is omitted.
NOTE:
The following CLASS DEFINEs do not return error 2058: CATALOG, DEFAULTS, MAP,
SEARCH, and SUBSORT.
If the consistency check failed for a TAPECATALOG DEFINE, the consistency check number returned
indicates the cause.
Code
Meaning
001
Use RETENTION or EXPIRATION, but not both.
005
If RECFORM F is specified, BLOCKLEN must be a multiple of RECLEN.
006
Use DEVICE or AVRSYSTEM, but not both.
101
USE cannot be used with LABELS OMITTED.
102
USE is required.
103
FILEID is required.
104
CATALOG OFF is required when LABELS BYPASS or LABELS OMITTED is used.
105
COMMENT, OWNER, RETENTION, TAPEMODE, VERSION NEW, and VOLUME SCRATCH cannot be used
with USE IN.
106
VOLUME is required with USE EXTEND.
107
DEVICE is required when LABELS BYPASS or LABELS OMITTED is used.
108
VOLUME is required when LABELS ANSI, LABELS BACKUP, LABELS IBM, or LABELS IBMBACKUP is used with
USE IN and CATALOG OFF.
109
The character string for OWNER exceeds the maximum length for LABELS IBM or LABELS IBMBACKUP.
1 10
BLOCKLEN, RECFORM, and RECLEN cannot be used with LABELS BACKUP, LABELS BYPASS, or LABELS
OMITTED.
1 12
EBCDIC can be used only with LABELS IBM or LABELS IBMBACKUP.
1 13
AVRSYSTEM, COMMENT, FILECAT, FILEID, GEN, OWNER, POOL, RETENTION, USE, VERSION, and VOLCAT
cannot be used with LABELS BYPASS.
1 14
AVRSYSTEM, OWNER, and VOLUME cannot be used with LABELS OMITTED.
1 15
USE EXTEND cannot be used with LABELS BACKUP or LABELS IBMBACKUP.
1 16
GEN must be an absolute value when CATALOG OFF is used.