2-5
Duplex INPUT JAM
•
Is the leading edge of paper is fed in the Duplex unit?
•
Yes
•
No
•
No
•
No
Does the square-shaped connector between the Duplex unit and printer unit has
any trouble?(Is there a pin bend or other troubles?)
•
Yes
•
No
•
No
Replace the square-shaped connector (Connector (IMSA-9714N-14A)).
40930701TH DRAFT Vesion
Has the leading edge of paper reached the Duplex In sensor
• Yes
Is the Duplex In sensor lever operating normally?
•
Yes
Is the connection cord between the Duplex In sensor and
the Board-LEX connected properly?
•
•
No
Connect the connection cord properly.
• No
Replace the Duplex In sensor lever (LEVER-Sensor (D-IN) and
SPRING-Sensor (D-IN)).
Is the connection cord between the Motor and the Board-LEX?
• Yes
Replace the GEAR Assy.
• YES END
• No
Replace the Motor.
• YES END
• No
Replace the Board-LEX.
Connect the connection cord properly.
Is the connection cord between the Duplex unit and the printer unit connected
properly?(See Chapter 7.1 and Appendix C Chapter 5.1)
• Yes
Does the connection cord have a break?
•
Yes
Replace the connection cord (Core Assy-DUPLEX).
• No
Is the connection between the solenoid and the Board-LEX connected
properly?
•
Yes
Replace the SOLENOID Assy.
•
YES
END
•
No
Replace the Board-LEX.
• No
Connect the connection cord properly.
Connect the connection cord properly.
Yes
Does the connection cord have a break?
•
Yes
Replace the connection cord
(Connection Code-Wire).
•
No
Replace the Duplex In sensor (FX50
Photo Sensor)
•
YES
END
144 /