Oki OKIPAGE24DX Maintenance Manual page 130

Led page printer
Hide thumbs Also See for OKIPAGE24DX:
Table of Contents

Advertisement

From on the preceding page
From on the preceding page
Yes
Is the printer recovered?
YES END.
No
Is the heater or thermistor open?
Measure the resistance between the thermistor contacts, and between heater
contacts (normal resistance: 220 k (25 C) between pins 1 and 2, 1.5
and 5.8
Yes
No
Is the AC voltage applied to the CN2 connector on the Power Supply Unit
(AC120V or 230V)? (See Figure 6-3)
No
Yes
Yes
YES
Go to
40930701TH DRAFT Vesion
A
.
.
B
Replace the fuser unit.
• No
Replace the Main board.
(240 V) between pins 3 and 4) (See Chapter 7.3.)
Replace the fuser unit.
Is CN2 connector connected to the Power Supply Unit (AC120V or 230V)?
• No
Connect the CN2 connector to the Power Supply Unit (AC120V or
230V) properly.
Is Pin 6 (HEAT ON signal) of the POWER connector of the Main board turned
on? (In heater on state, this pin is set to 0 V).
• No
Replace the Main board.
Replace the Power Supply Unit (High Voltage).
.
B
(120 V)