5
I/F time-out between printer and optional tray (ERROR 81) .
•
Is an optional tray (2nd / 3rd tray or envelope feeder) used?
•
Yes
•
Yes
•
Is the printer recovered?
•
YES END
•
No
Replace the Main board.
6
I/F time-out between printer and Duplex Unit (ERROR 83)
•
Is an Duplex Unit used?
•
Yes
•
Yes
•
Is the printer recovered?
•
YES END
•
No
Replace the Main board.
7
I/F time-out occurs between the printer and the operator panel (ERROR 80) .
•
Is the connecting cord of the operator panel connected to the PANEL connector of the
Main board properly? (See Chapter 7.1.)
•
No
•
Yes
•
Yes
•
No
•
Is the printer recovered?
•
No
•
YES END
40930701TH DRAFT Vesion
Is the connection between the Main board and the optional tray connected
properly. (See Chapter 7.1.)
• No
Connect the cable properly.
Replace the Main board.
• No
Isolate the trouble by following the 2nd/ 3rd tray or multi feeder
maintenance manual. (See Appendix C or D.)
Is the connection between the Main board and the Duplex Unit connected
properly. (See Chapter 7.1.)
• No
Connect the cable properly.
Replace the Main board.
• No
Isolate the trouble by following the Duplex Unit maintenance manual.
(See appendix C.)
Connect the connecting cord of the operating panel to the PANEL connector of
the Main board properly.
Is the connecting cord defective?
Replace the connecting cord.
Replace the operator panel assembly.
Replace the Main board.