Ve_Port Class Default Settings; Port Type: E_Port, Fop_Port, Or Fcu_Port; Table 19 Ve_Port Class Default Settings - Brocade Communications Systems StoreFabric SN6500B Administrator's Manual

Brocade fabric watch administrator's guide v7.1.0 (53-1002752-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

7
portThConfig command procedures

VE_Port class default settings

Table 19
not supported in Access Gateway mode.
NOTE
Only a subset of areas, shown in
VE_Port thresholds for the Packet Loss area, the threshold value accepts up to two decimal points;
for example: -value 0.60, as shown in
TABLE 19
Area
Packet Loss
State changes (ST)
Utilization
Packet loss monitoring enhancements on the VE_Port
Fabric Watch provides monitoring for packet loss percentage for the VE_Port. Previously,
configuring the packet loss percentage for the VE_Port was allowed as a whole number; however,
packet loss is usually found at less than one percent. Now there is support for configuring packet
loss percentages in decimals.
To set the high threshold for packet loss for a VE port, enter the portThConfig command using the
following parameters:
switch:admin> portthconfig
-trigger above -action snmp

Port type: E_Port, FOP_Port, or FCU_Port

E_Port, FOP_Port, and FCU_Port guidelines represent a more aggressive approach in most areas
than physical port guidelines. Refer to
"FOP_Port and FCU_Port subclass setting guidelines"
recommendations.
68
provides default settings (per minute) for areas in the VE_Port class. The VE_Port type is
Table
VE_Port class default settings
Description
The number of
packets routed
through a port
exceeds the port
bandwidth.
Monitors state
changes.
The percent of
utilization for the
port at the time of
the last poll.
--
set ve-port -area PKTLOSS -highthreshold -value 0.60
19, can be configured for the VE_Port class. When setting
"Packet loss monitoring enhancements on the
Default threshold
Default alarm settings
settings
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 10
Buffer: 0
Unit: Changes
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 50
Buffer: 0
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 100
Buffer: 0
"E_Port subclass setting guidelines"
on page 64 for configuration
VE_Port".
Threshold state
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
on page 61 and
Fabric Watch Administrator's Guide
53-1002752-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric watch

Table of Contents