VE_Port class default settings

Table 18
TABLE 18
Area
Packet Loss
State Changes
Utilization
Fabric Watch Administrator's Guide
53-1001770-01
provides default settings (per minute) for areas in the VE_Port class.
VE_Port class default settings
Description
The number of
packets routed
through a port
exceeds the port
bandwidth.
Monitors state
changes
The percent of
utilization for the
port at the time of
the last poll.
Port class guidelines and default settings
Default threshold
Default alarm settings
settings
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 10
In-Between: 0
Buffer: 0
Unit: Changes
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 50
In-Between: 0
Buffer: 0
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 100
In-Between: 0
Buffer: 0
7
Threshold state
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range