4. Click the Alarm Configuration tab.
5. Select SNMP Trap, RAS log, or both options.
6. Click Apply.

Fabric Watch threshold configuration using Web Tools

The Threshold Configuration tab enables you to configure event conditions. From this tab, you
configure threshold traits, alarms, and e-mail configurations.
NOTE
Use the procedures in this section to configure threshold traits for all classes except for the FRU
class. Use the procedure described in
the FRU class.
Configuring threshold traits
Configure threshold traits to define a threshold for a particular class and area. You can configure
the following traits for a threshold:
NOTE
When you are configuring the VE-Port > Packet Loss area thresholds, the packet loss threshold
values are a percentage. You can configure from 0.01% (low boundary) to 100.00% (high boundary).
To configure threshold traits, perform the following steps.
1. Click Fabric Watch in the Manage section of the Tasks menu.
2. Select the Threshold Configuration tab.
3. Select the Trait Configuration subtab.
4. In Fabric Watch Explorer, select a class.
5. Under Area Selection, select an area from the list.
6. In the Activate Level area:
7.
8. Enter the lowest boundary of the normal zone in the Low Boundary field.
Fabric Watch Administrator's Guide
53-1002752-01
Time Base—The time base (minute, hour, day) for the area
Low Boundary—The low threshold for the event-setting comparisons
High Boundary—The high threshold for the event-setting comparisons
Buffer Size—The size of the buffer zone used in event-setting comparisons
This sets the units in the Units field.
The module displays two columns of trait information, labeled System Default and Custom
Defined. You cannot modify the information in the System Default column.
Use the system default settings and proceed to
or
Click Custom Defined to specify new settings and proceed to the next step.
If necessary, select a time to record the event in the Time Base field.