Setting Fabric Watch custom and default values
Use the following commands to switch between custom and default values. These commands reset
all thresholds for all classes:
•
•
E-mail notification configuration
In environments where it is critical that you are notified about errors quickly, you can use e-mail
notifications. With e-mail notifications, you can be notified of serious errors by e-mail or a pager, so
you can react quickly.
To configure e-mail notifications in a Telnet session, perform the following steps.
1. Enter the fwMailCfg command at the prompt.
2. Enter the number corresponding to the task you wish to perform.
Showing e-mail configuration information
1. Enter 1 in the fwMailCfg menu to view the current e-mail configuration classes.
Fabric Watch Administrator's Guide
53-1002752-01
fwSetToCustom - Sets the boundary and alarm level to custom.
fwSetToDefault - Restores the boundary and alarm level to the default.
The fwMailcfg menu displays.
1
: Show Mail Configuration Information
2
: Disable Email Alert
3
: Enable Email Alert
4
: Send Test Mail
5
: Set Recipient Mail Address for Email Alert
6
: Relay Host IP Configuration
7
: Quit
Select an item
=> : (1..7) [7]
The Config Show menu displays.
Config Show Menu
____________________________
1
: Environment class
2
: SFP class
3
: Port class
4
: Fabric class
5
: E-Port class
6
: F/FL Port (Optical) class
7
: Alpa Performance Monitor class
8
: End-to-End Performance Monitor class
9
: Filter Performance Monitor class
10 : Security class
11 : Resource class
12 : FRU class
13 : Quit
Select an item
=> : (1..13) [13]
Setting Fabric Watch custom and default values
5
31
Need help?
Do you have a question about the StoreFabric SN6500B and is the answer not in the manual?
Questions and answers