Physical Port Setting Guidelines; Port Class Default Settings; Table 16 Port Class Default Settings - Brocade Communications Systems StoreFabric SN6500B Administrator's Manual

Brocade fabric watch administrator's guide v7.1.0 (53-1002752-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

Physical port setting guidelines

It is recommended that you use the default settings listed in
Consider the Port class to be a superset containing the E_Port, FOP_Port, and FCU_Port
subclasses. If you make a change to a default setting for an area in the Port class, it applies to all of
the subclasses. This is convenient if you have determined that changes you plan to make to the
default settings for the subclasses are the same for certain areas. In this case, you only need to
make the changes to the Port class. Note, however, that if you make a change to one of the
subclasses, that change overrides the Port class setting.

Port class default settings

Table 16
TABLE 16
Area
Cyclic redundancy
check (CRC)
Invalid transmission
words (ITW)
Class 3 discards
(C3TX_T0)
Link loss
Signal loss
State changes (ST)
Sync loss
Fabric Watch Administrator's Guide
53-1002752-01
provides default settings for areas in the Port class.
Port class default settings
Description
Monitors the
number of CRC
errors.
Monitors the
number of invalid
words transmitted.
Class 3 discards
frames due to time
out or destination
unreachable.
Monitors the
number of link
failures.
Monitors the
number of signal
loss errors.
Monitors state
changes.
Monitors the
number of loss of
synchronization
errors.
Port class guidelines and default settings
Table 16
Default threshold
Default alarm settings
settings
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 1000
Buffer: 100
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 1000
Buffer: 100
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 2
Buffer: 0
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 500
Buffer: 50
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 5
Buffer: 0
Unit: Changes
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 50
Buffer: 0
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 500
Buffer: 50
7
for most Port class areas.
Threshold state
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
57