Environment monitoring
Environment monitoring setting guidelines
Use Environment Class default settings. Temperature settings are switch-dependent and there is
no need to alter them. The default alarm configuration, sending alerts to the error log and SNMP, is
sufficient.
Environment class default settings
Table 24
hardware reference manual for differences in actual environmental requirements.
NOTE
Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring
and the switch status is calculated based on the fan status reported by EM.
TABLE 24
Area
Temperature
76
provides default Environment class settings for all switches. Check the appropriate
Environment class default settings
Description
Monitors switch
temperature in
Celsius
Default threshold
Default alarm settings
settings
Unit: degrees C
Below: 3
Time Base: none
Above: 3
Brocade 200E
(Same setting for all
Low: 0
devices)
High: 60
Buffer: 10
Brocade 300
Low: 0
High: 50
Buffer: 10
Brocade 5100
Low: 0
High: 63
Buffer: 10
Brocade 5300
Low: 0
High: 48
Buffer: 10
Brocade 7500
Low: 0
High: 63
Buffer: 10
Brocade 7600
Low: 0
High: 63
Buffer: 10
Brocade 7800
Low: 0
High: 58
Buffer: 10
Threshold state
Out-of-range
Out-of-range
(Same setting for all
devices except
Brocade DCX-4S)