[Install] Install

Example 1: installing additional channel adapters
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Install,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{CHA,Kind}={CHA-1EL,16FC (Fibre )},
++{Port,Initiator/Target,Channel Speed,CU Number}
=[{1C,Target,Auto,00:00-00:FE},{3C,Target,Auto,00:00-00:FE},
{5C,Target,Auto,00:00-00:FE},{7C,Target,Auto,00:00-00:FE},
{1D,Target,Auto,00:00-00:FE},{3D,Target,Auto,00:00-00:FE},
{5D,Target,Auto,00:00-00:FE},{7D,Target,Auto,00:00-00:FE}],
Num. of Ports=8
+{CHA,Kind}={CHA-1FU, 16MF(Mfibre)},
++{Port,HTP/FNP,CU Number,Emulation}
=[{1E,HTP,00:00-00:FE,I-2107},{3E,HTP,00:00-00:FE,I-2107},
{5E,HTP,00:00-00:FE,I-2107},
{7E,HTP,00:00-00:FE,I-2107},{1F,HTP,00:00-00:FE,I-2107},
{3F,HTP,00:00-00:FE,I-2107},{5F,HTP,00:00-00:FE,I-2107},
{7F,HTP,00:00-00:FE,I-2107}],Num. of Ports=8
+{CHA,Kind}={CHA-2QL,16FC (Fibre )},
++{Port,Initiator/Target,Channel Speed,CU Number}
=[{2C,Target,Auto,00:00-00:FE},{4C,Target,Auto,00:00-00:FE},
{6C,Target,Auto,00:00-00:FE},{8C,Target,Auto,00:00-00:FE},
{2D,Target,Auto,00:00-00:FE},{4D,Target,Auto,00:00-00:FE},
{6D,Target,Auto,00:00-00:FE},{8D,Target,Auto,00:00-00:FE}],
Num. of Ports=8
+{CHA,Kind}={CHA-2RU, 16MF(Mfibre)},
++{Port,HTP/FNP,CU Number,Emulation}
=[{2E,HTP,00:00-00:FE,I-2107},{4E,HTP,00:00-00:FE,I-2107},
{6E,HTP,00:00-00:FE,I-2107},{8E,HTP,00:00-00:FE,I-2107},
{2F,HTP,00:00-00:FE,I-2107},{4F,HTP,00:00-00:FE,I-2107},
{6F,HTP,00:00-00:FE,I-2107},{8F,HTP,00:00-00:FE,I-2107}],
Num. of Ports=8
+Num. of CHAs=4
Detailed Information for Example 1
Item
CHA
Kind
Port
Initiator/Target
Channel Speed
CU Number
Num. of Ports
HTP/FNP
Emulation
Num. of CHAs
Example 2: installing additional subsystems, ECC Groups or LDEVs
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Install,,Normal end,
Description
The CHA mounting location.
The kind of PCB mounted.
The mounting location of the port.
The type of Initiator or Target.
The channel speed is indicated for open systems.
1: 1 Gbps, 2: 2 Gbps, 4: 4 Gbps, 8: 8 Gbps, Auto: Auto mode.
Indicates the range of the CU number that the port belongs.
The number of ports.
The HTP or FNP is indicated for FICON.
The emulation type is indicated for mainframe systems.
The number of CHAs.