[Shredder] Shred LDEVs

This logged information indicates that the Shredding operation was only requested but not
completed.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Shredder],Shred LDEVs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+OwnerID=0
+{Data, Output File}
=[{0xffff,Disable},{Random,Disable},{0x00,Enable}],Num. of Data=3
+Output LDEV
=[0x00:0x00:0x00,0x00:0x00:0x01,0x00:0x00:0x02],Num. of LDEVs=3
+Shred LDEV=[0x00:0x00:0x00,0x00:0x00:0x01,0x00:0x00:0x02],
Num. of LDEVs=3
Detailed Information
Item
OwnerID
Data
Output File
Num. of Data
Output LDEV
Num. of LDEVs
Shred LDEV
Num. of LDEVs

Compatible XRC Descriptions

[XRC] Set XRC Option

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[XRC],Set XRC Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{CLPR,LV2 THD(%),Block Option,Donot Block,LV1 Sleep,
Sleep Time(ms),LV1 SIM,LV2 Suspend}
=[{00,50,Cache,Disable,Disable,100,Disable,
Disable},
-{01,70,Cache,Enable ,Disable,10,Disable,Disable},
-{02,60,Cache,Disable,Disable, 10,Enable ,Enable }],
Num. of CLPRs=32
188 Audit log examples
Description
The owner ID
0: Indicates Remote Web Console
0xXX: Owner ID is expressed in two digits of the hexadecimal format
The shredding data pattern
Random: Random, 0xXXXX: Define
Whether the result of shredding is output to the file
Disable: No output, Enable: Output
The number of shredding data patterns
Indicates LDEVs whose shredding results are output to the file
The number of target LDEVs of Data output
The LDEV to be shredded
The number of LDEVs to be shredded