Item
LDKC:CU:LDEV
CommandDev
Num. of LDEVs

[PROV] Edit DRU Attribute

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[PROV],Edit DRU Attribute,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC:CU:LDEV,Attribute,RT,Result}
=[{0x00:0x00:0x01,0x80,100,Normal end},
{0x00:0x00:0x02,0x82,Unlimited,Error(9605-8122)},
{0x00:0x00:0x03,0x81,200,Normal end},
{0x00:0x00:0x03,0x81,xxxx,Normal end}],
Num. of LDEVs=XXX
Detailed Information
Item
LDKC:CU:LDEV
Attribute
RT
Result
Num. of LDEVs
* When bit 5, 6, and 7 are all 0 (zero), Read/Write has been set.
1 10
Audit log examples
Description
The LDKC, CU, and LDEV numbers of the logical volume where the command device setting is
changed.
Indicates whether the command device setting is enabled or disabled.
Disable or Enable will appear.
The number of logical volumes where the command device setting is changed.
Description
The LDKC, CU, and LDEV numbers of the logical volume where the attribute is set.
The set attribute in hexadecimal. Each bit (0–7) of 1 byte corresponds to the setting item. 1 is
assigned to each bit when the setting is enabled and 0 (zero) is assigned to each bit when
the setting is disabled. Each bit represents the following attributes:
Bit 0: Mounting of LEDV (fixed to 1)
Bit 1: Setting of S-VOL Disable
Bit 2: Setting of Zero Read Cap mode
Bit 3: Setting of Invisible mode
Bit 4: Setting of reserve
*
Bit 5: Fixed to 0 (zero)
Bit 6: Setting of Read Only attribute
Bit 7: Setting of Protect attribute
When 0x88 is output to the attribute, for example, Read/Write attribute is set to the logical
volume to show that the reserve setting has been enabled.
A hyphen (-) is output when setting is not changed.
The number of days set in Retention Term.
A hyphen (-) is output when setting is not changed.
The result of operation.
Normal end: Normal end, Error (xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of the logical volume(s) where the attribute has been set.
*
*