Item
Swap & Freeze
HOST I/O Performance
FC Z Slower Copy1
FC Z Slower Copy2
Reserve X
OFFLINE DATA MIGRATION

[BC Z] Resync Pair

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[BC Z],Resync Pair,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy pace=Faster,Resync Type=Normal Copy
++{S-VOL(LDKC:CU:LDEV),T-VOL(LDKC:CU:LDEV),Result}
=[{0xXX:0xAA:0xBB,0xYY:0xCC:0xDD,Normal end},
{0xXX:0xAA:0xBB,0xYY:0xCC:0xDD,Error(xxxx-yyyy)}],
Num. of Pairs=2
Detailed Information
Item
Copy Pace
Resync Type
S-VOL(LDKC:CU:LDEV)
T-VOL(LDKC:CU:LDEV)
Result
Num. of Pairs
144 Audit log examples
Description
Indicates whether the Swap & Freeze option is enabled or disabled.
Enable: Option is enabled, Disable: Option is disabled.
Indicates whether the host I/O option is enabled or disabled.
Enable: Option is enabled, Disable: Option is disabled.
Indicates whether FC Slower Copy1 option is enabled or disabled.
Enable: Option is enabled, Disable: Option is disabled.
Indicates whether the FC Slower Copy 2 option is enabled or disabled.
Enable: Option is enabled, Disable: Option is disabled.
Reserved items. X is the number from 05 to 32.
Indicates whether the OFFLINE DATA MIGRATION option is enabled or
disabled.
Enable: Option is enabled, Disable:Option is disabled.
This item may be displayed instead of Reserve 32.
Description
The set copy speed.
Faster: High speed, Medium: Medium speed, Slower: Low speed
The type of resynchronization.
Normal Copy: Normal resynchronization, Quick Resync: High speed resynchronization,
Reserve Copy: Reverse resynchronization, Quick Restore: High speed restore, Migration:
Data migration
The LDKC, CU, and LDEV numbers of the source volume in the resynchronized pair.
The LDKC, CU, and LDEV numbers of the target volume in the resynchronized pair.
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of resynchronized pairs.