HP StorageWorks P9000 - Disk Arrays Reference Manual page 64

Hp storageworks p9000 audit log user and reference guide (av400-96333, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{DKA,Kind}=[{DKA-1AL,DKF 4MP},{DKA-1LL,DKF 4MP},
{DKA-2ML,DKF 4MP},{DKA-2XL,DKF 4MP}],Num. of DKAs=4
+{DKU,Kind}=[{DKU-11,2.5" DKU}],Num. of DKUs=1
+{PG,RAID Level,Drive Type,Protection Level,Emulation,
Concatenation,Encryption}
={3-1,RAID1 (2D+2D),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x00,OPEN-V,2251536384,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+{PG,RAID Level,Drive Type,Protection Level,
Emulation,Concatenation,Encryption}
={3-2,RAID5 (3D+1P),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x01,OPEN-V,3377304576,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+{PG,RAID Level,Drive Type,Protection Level,
Emulation,Concatenation,Encryption}
={3-3,RAID1 (2D+2D),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x02,OPEN-V,2251536384,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+Num. of PGs=3
+{B4,SPARE,Drive Type}=[{3,1,DKR5C-J600SS}],Num. of SPAREs=1
This logged information indicates that the formatting was only requested but not finished. If the
operation does not require the formatting, this logged information indicates that the volume was
created.
Basic Information for Example 2
Parameter
Progress Close
Quick Format
Quick Format Close
Note: No parameter is output for any case other than those described in this table.
Detailed Information for Example 2
Item
Disk Adapter (DKA)
Kind
Num. of Disk Adapter
(DKA)s
Disk Unit (DKU)
Kind
Num. of Disk Unit
(DKU)s
PG
RAID Level
Drive Type
Protection Level
64
Audit log examples
Description
The progress window of LDEV format when LDEV is added is closed.
Quick Format was selected when LDEV is added.
The progress window of preparing for Quick Format is closed.
Description
The Disk Adapter (DKA) mounting location.
The type of Disk Adapter (DKA).
The number of Disk Adapter (DKA)s.
The mounting location of Disk Unit (DKU).
The type of DKU.
The number of Disk Unit (DKU).
The parity group number.
The RAID Level.
The type of the drive.
The protection level.

Advertisement

Table of Contents
loading

Table of Contents