Configuring Microsoft Mpio Iscsi Devices - HP StorageWorks MPX200 User Manual

Hp storageworks mpx200 multifunction router user guide (5697-0568, august 2010)
Hide thumbs Also See for StorageWorks MPX200:
Table of Contents

Advertisement

3.
mpathadm show lu logical-unit
This command displays details about a logical unit. Use this command to verify symmetric mode,
load balancing, and auto-failback settings, as well as path and target port information.
Example:
#mpathadm show lu /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
Logical Unit:
b2.01.50014380025c4179
b1.01.50014380025c417d
b2.01.50014380025c4179
b1.01.50014380025c417d

Configuring Microsoft MPIO iSCSI devices

For Microsoft MPIO, the load-balance policies apply to each LUN individually. To display and modify
the LUN load-balance policy
1.
Start the Microsoft iSCSI Control Panel applet.
2.
Select the Target tab.
3.
Click Details.
4.
Click Devices.
5.
Highlight a LUN device name, and then click Advanced.
6.
Select the MPIO check box.
96
MPX200 iSCSI configuration rules and guidelines
/dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2
mpath-support:
libmpscsi_vhci.so
Vendor:
HP
Product:
HSV300
Revision:
0005
Name Type:
unknown type
Name:
600508b4000b15a200005000038e0000
Asymmetric:
no
Current Load Balance:
Logical Unit Group ID:
Auto Failback:
off
Auto Probing:
NA
Paths:
Initiator Port Name:
Target Port Name:
Override Path:
Path State:
Disabled:
no
Initiator Port Name:
Target Port Name:
Override Path:
Path State:
Disabled:
no
Target Ports:
Name:
4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
Relative ID:
Name:
4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
Relative ID:
(Figure
68):
none
NA
iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
NA
OK
iqn.1986-03.com.sun:01:sansun-s04,4000002a00ff
4000002a0000,iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.
NA
OK
0
0

Advertisement