1.
Update the sgen driver:
# update_drv –a –I "scsiclass,0c" sgen
NOTE:
Lowercase c is mandatory.
2.
Verify the sgen alias setting:
#egrep sgen /etc/driver_aliases
Example:
# rep sgen /etc/driver_aliases
sgen "scsa,08.bfcp"
sgen "scsa,08.bvhci"
sgen "scsiclass,0c"
Enable iSCSI target discovery
Solaris supports three iSCSI target discovery methods:
SendTargets
Static
iSNS
This section describes SendTargets discovery only. For information on static and iSNS discovery, see
http://docs.sun.com/app/docs/doc/817-5093/fqnlk?l=en&=view.
To enable iSCSI target discovery:
1.
Enter the following command:
# iscsiadm modify discovery –t enable
2.
Verify that SendTargets is enabled:
# iscsiadm list discovery
3.
The MPX200 has multiple iSCSI ports available to the Solaris iSCSI initiator. To discover the
targets available, enter the following command for each iSCSI port IP address that the iSCSI
initiator accesses:
#iscsiadm add discovery-address 'iscsi port IP address'
4.
Verify the discovery address entries:
#iscsiadm list discovery-address
92