HP StorageWorks MPX200 User Manual page 236

Hp storageworks mpx200 multifunction router user guide (5697-0568, august 2010)
Hide thumbs Also See for StorageWorks MPX200:
Table of Contents

Advertisement

QLBA_CreateTargetDeviceOb-
41058
ject: Too many devices
QLBA_CreateTargetNodeObject:
41060
Too many devices
QLBA_CreateLunObject: LunOb-
41067
ject memory unavailable
QLBA_CreateInitiatorObject:
41077
Too many initiators
QLBA_DisplayTargetOperation-
41096
Status: PCI Error, Status
0x%.2x
QLBA_DisplayInitiatorOpera-
41106
tionStatus: DMA Error,
Status 0x%.2x
QLBA_DisplayInitiatorOpera-
41107
tionStatus: Transport Error,
Status 0x%.2x
QLBA_DisplayInitiatorOpera-
41111
tionStatus: Data Overrun,
Status 0x%.2x
QLIS_LoginPduContinue: Oper-
41234
ation failed. Initiator
0x%x, TPB status 0x%x
QLKV_ValidateLoginTransitC-
41238
sgNsgVersion failed (status
0x%x)
QLIS_LoginPduContinue: Inval-
41257
id initiator name. Initiat-
or:
QLIS_LoginPduContinue: Tar-
41265
get not configured for
Portal
QLIS_LoginPduContinue: Tar-
41267
get not found. Target name:
QLIS_LoginPduContinue: Miss-
41268
ing target name
236
Log messages
Unable to create an object for the
App
Error
target device; exceeded the max-
imum number of target devices.
Unable to create an object for the
App
Error
target node; exceeded the maxim-
um number of target devices.
Memory unavailable for LUN ob-
App
Error
ject.
Unable to create an object for initi-
App
Error
ator object; exceeded the maxim-
um number of initiators.
Process control block status indic-
ates that a peripheral component
App
Error
interface/interconnect (PCI) error
occurred during a target operation.
Process control block status indic-
ates that a direct memory access
App
Error
(DMA) error occurred during an
initiator operation.
Process control block status indic-
ates that a transport error (pro-
App
Error
tocol) occurred during an initiator
operation.
Process control block status indic-
ates that a data overrun error oc-
App
Error
curred during an initiator opera-
tion.
iSCSI login failed between receipt
App
Error
of protocol data unit (PDU) and
request for the data segment.
iSCSI login failed due to unsuppor-
App
Error
ted version number in received lo-
gin PDU.
iSCSI login PDU contains invalid
initiator name. The format and
App
Error
character set used to form the initi-
ator name is invalid.
iSCSI target login was attempted
App
Error
to a portal (iSCSI1 or iSCSI2) on
which the target is not presented.
iSCSI login PDU received for a
App
Error
target with a target name unknown
to the router.
iSCSI login PDU received without
App
Error
a target name for a normal ses-
sion.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp20000/xp24000

Table of Contents