HP StorageWorks MPX200 User Manual page 244

Hp storageworks mpx200 multifunction router user guide (5697-0568, august 2010)
Hide thumbs Also See for StorageWorks MPX200:
Table of Contents

Advertisement

#%d: QLProcessSystemError:
74705
Restart RISC
#%d: QLInitializeFW:
MBOX_CMD_INITIALIZE_FIRMWARE
74746
failed %04x %04x %04x %04x
%04x %04x
#%d: QLUpdateInitiatorData:
74784
No more room in Initiator
Database.
#%d: QLSetTargetData: No
74800
more room in Target Data-
base.
#%d: ql_process_error:
75008
OB_TCP_IOCB_RSP_W returned
DdbInx 0x%x pTpb %p
86347
#%d: QLDisable: Restart RISC
#%d: QLEnable: Restart RISC
86349
to update EEPROM
#%d: QLIsrDecodeMailbox:
86874
Link up
#%d: QLGetFwStateCallback:
87346
link 100Mb FDX
#%d: QLGetFwStateCallback:
87348
link 1000Mb FDX
#%d: QLGetFwStateCallback:
87350
Invalid link speed 0x%x
#%d: qlutm_init: Diagnostic
102419
failed, port 1 invalid SRAM
#%d: qlutm_init: Diagnostic
102420
failed, port 1 POST failed
#%d: qlutm_init: Diagnostic
102421
failed, port 2 invalid SRAM
#%d: qlutm_init: Diagnostic
102422
failed, port 2 POST failed
#%d: qlutm_init: Failed to
102423
return diagnostic result to
Bridge
#%d: QLInitializeAdapter:
102656
Reset ISP failed
244
Log messages
iSCSI
Error
iSCSI processor was restarted.
iSCSI processor rejected the firm-
iSCSI
Error
ware initialize command.
Driver's initiator database is full.
The driver is capable of storing
iSCSI
Error
1024 iSCSI initiators in its data-
base. Use the CLI or GUI to remove
unwanted/unused iSCSI initiators.
Driver's target database is full. Use
iSCSI
Error
the CLI or GUI to remove un-
wanted/unused iSCSI targets.
TCP retry for a frame failed on the
connection ddbIndex. Tpb con-
iSCSI
Error
tains the frame memory address.
iSCSI
Info
Restart iSCSI processor (RISC).
EEPROM updated, restart iSCSI
iSCSI
Info
processor (RISC).
Link up reported by iSCSI pro-
iSCSI
Info
cessor for GE1 or GE 2.
iSCSI controller reported a link
iSCSI
Info
speed/configuration of 100 Mb
full-duplex (FDX).
iSCSI controller reported a link
iSCSI
Info
speed/configuration of 1000 Mb
FDX.
iSCSI controller reported an invalid
iSCSI
Info
link speed.
FC
Fatal
FC1 processor SRAM test failed.
FC1 processor power-on self-test
FC
Fatal
(POST) failed.
FC
Fatal
FC2 processor SRAM test failed.
FC
Fatal
FC2 processor POST failed.
FC processor failed to return dia-
FC
Fatal
gnostic results.
FC
Fatal
FC processor failed reset.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp20000/xp24000

Table of Contents