3.
Enable CHAP for the Microsoft iSCSI initiator.
a.
Select the General tab.
b.
Click Secret in the middle of the screen.
c.
Click Reset.
d.
Enter the MPX200 iSCSI Presented Target CHAP secret (for example: hpstorageworks).
e.
Click Discovery.
• To discover iSCSI target portals manually:
a.
b.
c.
d.
e.
f.
• Using iSNS for target discovery:
a.
b.
c.
f.
Click Targets.
g.
Select the appropriate target for login.
h.
Click Log On.
i.
Click Advanced.
j.
Select the CHAP Login Information check box.
k.
Enter the CHAP secret for the MPX200 discovered iSCSI initiator in the Target Secret box
(for example: CHAPsecret01).
l.
Select the Mutual Authentication check box.
m. Click OK.
n.
Click OK and the initiator completes normal login.
Enabling bidirectional CHAP during discovery session and single-direction CHAP
during normal session
Table 14
lists the settings you use to enable bidirectional CHAP during a discovery session and
single-direction CHAP during a normal session.
Table 14 CHAP bidirectional settings
MPX200 secret settings
Source
112
MPX200 iSCSI configuration rules and guidelines
Click Add under Target Portals.
Enter the IP address of the iSCSI port of the MPX200.
Click Advanced.
Select the CHAP Login Information check box.
Enter the CHAP secret for the MPX200 discovered iSCSI initiator in the Target Secret
box (for example: CHAPsecret01).
Click OK.
The initiator completes target discovery.
Click Add under iSNS Servers.
Enter the IP address of the iSNS server.
Click OK.
Setting (example)
Microsoft initiator secret settings
Action
Setting (example)