You can shut down a DFE‐Gold module in an operating system using the 
OFFLINE/RESET
DFE‐Gold module.
"Recommended Shutdown Procedure Using OFFLINE/RESET Switch" (page 4‐7) 
"Last Resort Shutdown Procedure Using OFFLINE/RESET Switch" (page 4‐8)
Figure 4-2
1 OFFLINE/RESET switch (in similar location on all DFE modules)
Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
Caution: Do not remove a DFE module from an operating chassis system before reading
the following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.
Before pulling a DFE‐Gold module out of a chassis, 
press or tap on its OFFLINE/RESET switch for less than 1 second. 
Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the module is shutting down. At the end of the shutdown routine, the CPU LED 
changes to a 67%/33% sequence of amber/off, respectively, indicating the module is in a 
halt state. In this time it is safe to restart or remove the module from the chassis.
switch
 shown in Figure

OFFLINE/RESET Switch

DFE-Gold Module Shutdown Procedure
4‐2. There are two procedures to shut down a 
À
Matrix DFE-Gold Series Installation Guide 4-7