Connecting Utp Cables - Enterasys Gold Distributed Forwarding Engine 4G4282-49 Hardware Installation Manual

Enterasys networks switch hardware installation guide
Table of Contents

Advertisement

Connecting to the Network

Connecting UTP Cables

The fixed RJ45 front panel connections of the 4G4202‐72 and 4G4282‐49 are 10/100/1000 
Mbps ports. These ports have internal crossovers, and also support automatic‐polarity 
sensing when configured for automatic‐negotiation.
If automatic‐negotiation is not activated on a port, use a straight‐through cable when 
connecting a workstation to the port. When connecting a networking device to the port, 
such as a bridge, repeater, or router, use a crossover cable.
If a port is set for auto‐negotiation, automatic‐polarity sensing is also activated. 
Automatic‐polarity sensing eliminates the need for a crossover cable, whether the 
connection is to another network device or a workstation.
In this procedure, the 4G4202‐72 is used as the example to connect a twisted pair segment 
to the module. It is also assumed that the chassis power is turned on to provide power to 
the module. Refer to Figure
1.
Ensure that the device connected to the other end of the segment is powered ON.
2.
Connect the twisted pair segment to the module by inserting the RJ45 connector on 
the twisted pair segment into the appropriate RJ45 port connector. 
3.
Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing 
amber, blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) 
LED is not blinking amber, perform the following steps until it is on:
a.
b. Verify that the cabling being used is Category 5 UTP with an impedance between 
c.
d. Verify that the RJ45 connectors on the twisted pair segment have the proper 
3-16 Installation
Note: All RJ45 front panel ports on the 4G4202-72
Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms.
Category 3 cable may be used if the connection is going to be used only for 10 Mbps.
3‐8 on page 3‐17 and proceed as follows:
To view the receive and transmit activity on a group of segments, press the 
GROUP SELECT button (see Figure
interest (Groups 1 through 3 on the 4G4202‐72, or Groups 1 through 5 on the 
4G4282‐49). Each time the GROUP SELECT button is pressed, a GROUP LED 
lights up in sequence, indicating which Group is selected. The receive and 
transmit activity for that group of segments is then indicated by the RX and TX 
LEDs for each segment.
85 and 111 ohms. For the port to operate at 100 or 1000 Mbps, Category 5 cabling 
must be used and installed properly.
Verify that the device at the other end of the twisted pair segment is on and 
properly connected to the segment.
pinouts and check the cable for continuity. Typically, a crossover cable is used 
between network devices. A straight‐through cable is used to connect between 
switches or hub devices and an end system (computer). Refer to Figure
4G4282-49 support Category 5
 and 
3‐8 on page 3‐17) to step to the group of 
3‐9 and 