Setting The Outputs Parameter (Output) - Duerkopp Adler 869-M PREMIUM Operating Instructions Manual

Table of Contents

Advertisement

Programming
Operating Instructions 868-M PREMIUM - 02.0 - 01/2018
Setting: Distance after detection of end of material (Distance)
Here, you can set the distance from the detection of the signal to
the end of the material. This distance signifies the path from the
needle to the light barrier. The path is specified in millimeters and
used by the machine to independently calculate the number of
stitches.
Setting: Number of signal detections (Seams)
Input of the number of signal detections after which the machine
is supposed to continue with the specifically set parameters.
Setting: Filter stitches up to signal detection (Filter)
Loosely woven fabric with stitches may cause the light barrier to
wrongly detect a signal. To prevent this from happening, you enter
the number of filter stitches. This number represents the minimum
number of stitches with signal detection following the 1
of the signal.

5.4.16 Setting the Outputs parameter (Output)

This parameter provides virtual outputs that can be assigned
customer-specific functions. They can be used when customer-
specific applications require a signal from the control of the
machine.
These parameters cannot be used unless the virtual outputs have
been assigned to a physical output at the Technician level.
This requires that the parameter Add I/O be configured at the
Technician level; for more details, refer to the explanation in the
 Service Instructions.
st
detection
89