C. Registration Roller
Assembly
1. Removing the Registration Roller
Assembly
1) Remove the developing assembly. (See p.
4-37.)
2) Remove the drum unit. (See p. 4-28.)
3) Remove the multifeeder assembly. (See p.
5-20.)
4) Disconnect the connector [1], and remove
the grip right [2]; then, detach the
registration roller clutch [3].
5) Disconnect the connector [4], and remove
the three mounting screws [5]; then,
detach the registration roller assembly [6].
COPYRIGHT © 1998 CANON INC.
CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 PICK-UP/FEEDING SYSTEM
[2]
Figure 5-622
[5]
[5]
Figure 5-623
[1]
[3]
[6]
[4]
5–23