Chapter 8 Installation; Selecting The Site - Canon NP7160 Service Manual

Hide thumbs Also See for NP7160:
Table of Contents

Advertisement

I. SELECTING THE SITE
Check the site of installation against the following requirements. If possible, visit the site in
advance of the delivery of the machine.
1. There must be a dedicated power outlet for exclusive use by the copier capable of providing
the rated voltage (±10%).
2. The temperature must be 7.5° to 32.5°C (45.5° to 90.5°F), and humidity must be 5% to 85%
RH. (Avoid areas near a water faucet, water boiler, humidifier, and refrigerator.)
3. Avoid areas near a source of fire and areas subject to dust or ammonia gas. Avoid direct rays
of the sun. As necessary, provide curtains.
4. The amount of ozone generated by the copier is of a level not affecting the health of the
individuals around it. Some individuals, however, may find its smell unpleasant. Be sure that
the room is properly ventilated.
5. Select a well-ventilated area. If multiple copiers are to be installed, in particular, make sure
that the exhaust from one will not be drawn into the vent of another.
6. Make sure that the copier will be level.
7. Keep the copier 10 cm (3.9 in) or more away from any wall to provide adequate space for
machine operation.
COPYRIGHT © 1998 CANON INC.
50cm/19.7in.
min.
Figure 8-101
CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)

CHAPTER 8 INSTALLATION

10cm/3.9in.
min.
50cm/19.7in.
min.
50cm/19.7in.
min.
8–1