Boot any of the nodes in stand-alone mode only if they are powered off, or select
all of the nodes in a partition to reboot at the same time. They then reboot at the
same time, without reporting the error listed in Example 4-8 on page 241.
Problem 2: Power state incorrect
A node in a configured partition results in becoming of unresponsive to requests
to control the partition by the scalability management menu.
The system power state is incorrectly shown as powered off.
How to identify the problem
In the scalability management menu, check the System power state of each
system in the partition. See Figure 4-34.
.
Partition ID: 1
SN: 23A0509
Primary
Port 1
Partition ID: 1
SN: 23A0143
Primary
Port 1
Figure 4-34 RSA II Web interface: two-node Partition configuration
As Figure 4-34 shows, the first system in the list is Stopped, however the second
system in the list is Started.
The power state is shown as Off in the Server Power/Restart Activity panel,
shown in Figure 4-35 on page 243.
242
Planning, Installing, and Managing the IBM System x3950 M2
(Local)
Port 2
Port 3
Port 2
Port 3
System
Mode
Partition
Stopped
Valid
Multinode
Started
Valid
Multinode