IBM 88743BU - System x3950 E User Manual page 196

Planning, installing, and managing
Table of Contents

Advertisement

Figure 3-69 Physical drive: offline drive state
Select one of the following options:
Mark Online: This sets the offline drive back to online.
Rebuild Drive: This starts the rebuilding with the selected disk at the virtual
disks that are in a
status window opens, so you can follow the progress, as shown in
Figure 3-70.
Figure 3-70 Physical drive: offline drive showing Rebuild Progress
Mark as Missing: This sets this command to mark this drive as missing.
Locate: This flashes the LED on the selected disk.
Failed
This shows you a physical disk that was configured as online or hotspare but
failed, but the controller firmware detected an unrecoverable error and marked
this disk as failed.
Tip: After a physical disk failed you should check the events at this disk. We
recommend to replace a failed disk. However after you have a valid backup for
any data you want to keep, you can try to rebuild this disk. If it failed or a
critical event is logged against this disk, replace it.
Missing
A missing drive is a physical drive that is removed or marked missing from an
enclosure and is a member of a configured virtual disk.
Tip: If the drive state is Missing but the drive is physically present, try
reseating it and seeing if that changes the state back to Unconfigured Good.
A physical disk previously forced to offline can be marked as missing also. See
"Offline" on page 177.
178
Planning, Installing, and Managing the IBM System x3950 M2
degraded
state. The drive state changes to
rebuild
. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 m2

Table of Contents