MERLIN LEGEND Communications System Release 5.0
System Programming and Maintenance (SPM) 555-650-140
System Programming and Maintenance
Using SPM
Restore is terminated under the following conditions:
If fewer boards are listed on the disk than on the control unit
If any real board is out of sequence with the boards listed on the disk
If phantom boards are not listed last
If the operating mode of the system being restored is Hybrid/PBX, but
the control unit processor module has been modified to operate only
in Key mode
A successful restore is followed automatically by a Restart (cold start)
!
WARNING:
An unsuccessful or terminated restore results in a System Erase
(frigid start). All calls are dropped. The system configuration is
erased. All system programming is lost and the system returns to
the factory settings. If the restore is being done remotely, the
connection is dropped immediately. If this happens, attempt to
reconnect to the control unit and immediately perform another
restore. If this is not successful, programming must be restored on
site.
Follow the steps below to perform a restore.
At the SPM Main Menu, press
 
SPM Main Menu
Menu: Select Function
Sys Program
Backup
Boards
Print Opts
Monitor
Follow the instructions for a floppy or a hard disk.
 
#
Maintenance
Restore
#
Pass-Thru
Password
Language
to select
Restore
Issue 1
June 1997