Lucent Technologies MERLIN LEGEND Release 5.0 System Programming And Maintenance Manual page 48

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Programming and Maintenance (SPM) 555-650-140
System Programming and Maintenance
Using SPM
Release 1.0 backups are uncompressed and Release 1.1 and later backups
are compressed. Uncompressed files take longer to restore.
Considerations
Review the following items before you begin the backup procedure:
The communications system does not have to be idle during backup;
however, extension programming is blocked.
Any objects that are in a maintenance-busy state are stored in that state.
When you restore system programming, these objects are busied out,
even if they have since been released from the maintenance-busy state.
If you plan to store your backup file on a diskette, format a DOS diskette.
(DOS formatting can be done on either a UNIX System PC or a
DOS PC).
Uncompressed backup files are 100,000 to 210,000 bytes in size;
compressed files are about 70,000 to 85,000 bytes.
Maintenance data (error logs and other data used by qualified service
technicians) is not saved in the backup file.
Follow the steps below to perform the backup procedure.
At the SPM Main Menu, press
 
SPM Main Menu
Menu: Select Function
Sys Program

Backup
Boards
Print Opts
Monitor

Maintenance
Restore
Pass-Thru
Password
Language
to select
.
Backup
Issue 1
June 1997
Page 34

Advertisement

Table of Contents
loading

Table of Contents