Connecting HA Servers to the Switch
Connecting to the Definity Switch
Distance Limits
Parts List
Quantity
(per CMS server)
1
1
2
1
*Parts for which no comcode is displayed must be obtained by the customer prior to the scheduled upgrade.
The maximum allowable length for a single segment of Cat 5 cable is 100
2
meters (328 feet); a maximum of four hubs can be used in series to
connect cable segments. Therefore, the distance between a local switch
and server must not exceed a maximum distance of 500 meters (1,640
feet).
However, when multiple ACDs are in use, few, if any, switches are likely
to be installed in the same physical location as the CMS servers. In most
cases, connections to the switches (both local and remote) are typically
made through a private network maintained by the customer.
The following parts list includes basic hardware items required to connect
2
each dual ACD link to a CMS HA server according to the recommended
connectivity configuration. For multiple dual link connections, additional
part quantities may be required for some components.
TN799 C-LAN port
259A adapter, or
258B adapter, or
356A adapter, or
Category 5 cross-connect hardware and connecting block
RJ45 UTP Category 5 modular cord:
5 feet, 1.5 meters
10 feet, 3 meters
15 feet, 4.5 meters
25 feet, 7.6 meters
50 feet, 15.2 meters
100 feet, 30.5 meters
200 feet, 61 meters
300 feet, 91 meters
CenterCOM 10Base-T LAN Hub
CentreVu CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Description
2-7
*
Comcode
N/A
102631413
103923025
104158829
N/A
107748063
107748105
107748188
107742322
107742330
107748238
107748246
107748253
407086735
Need help?