Autoimage Setup, Write - Barco RLM series User Manual

Rs232 commands
Table of Contents

Advertisement

3. Advanced Commands
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Awnser)
Start
Projector address
Command[0]
Command[1]
Data [0]
Data [1]
Checksum
Stop

3.18 AutoImage setup, Write

Description
Sets up the AutoImage i.e. selects the AutoImage parameters.
Command
Command [0]
Command [1]
Data
Unsigned word.see chapter "1. Serial communications Basics", "Data words", page 6
Data[0] = unsigned byte (msb)
Data[1] = unsigned byte (lsb)
Parameter
Total Pixels
Contrast/Brightness
Phase
Start pixel/line
Total pixels + cont/bright
...
Example
Set up AutoImage for "Total Pixels"
132
Data[0]
0000
0000
0000
0000
0000
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x86
\x10
\x00
\xb8
\xff
\x20
\x90
Data[1]
0001
0010
0100
1000
0011
R5976884 RLM SERIES 04/04/2006
Hex Value
\x01
\x02
\x04
\x08
\x03

Advertisement