Color Temperature, Read - Barco RLM series User Manual

Rs232 commands
Table of Contents

Advertisement

Color temperature
Projector white
Broadcast
Film
Video
Computer
If Data[0] is ommited current used colortemp is returned
Returned Data
Unsigned 2 byte word (msb-lsb).see chapter "1. Serial communications Basics", "Data words", page 6
Data [0] = unsigned byte (msb)
Data [1] = unsigned byte (lsb)

2.32.5 Color temperature, Read

Description
Reads the actual preset color temperature value from the projector
Commands
Command [0]
Command [1]
Returned Data
Data [0] = unsigned byte
data values: \x00 = projector white ; \x20 = broadcast ; \x36 = Film ;\x41 = Video ; \x5D = Computer ; \xff
= custom
Example
Reads the actual preset color temperature of the projector, the awnser being \x00 = projector white
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
R5976884 RLM SERIES 04/04/2006
Data[0]
\x00
\x20
\x36
\x41
\x5d
\x21
\x45
\xfe
\x01
\x21
\x45
\x67
\xff
\xfe
\x01
\x00