Pip Window Vertical Position, Read Min/Max; Pip Priority Write - Barco RLM series User Manual

Rs232 commands
Table of Contents

Advertisement

3. Advanced Commands
Note that the panel size (projector version) can be read using the Panel size command

3.2.29 PiP Window vertical position, Read Min/Max

Description
Reads the minimum/maximum value for the window vertical position adjustments in PiP.
Commands
read minimum:
Command [0]
Command [1]
read maximum:
Command[0]
Command[1]
Returned Data
Data[0]...Data[3] = signed double word Yposition : describes the min/max "heigth" of the window (y axis).
Note that the panel size (projector version) can be read using the Panel size command

3.2.30 PiP Priority Write

Description
Sets the priority (order) of a particular window
Command
Command [0]
Command [1]
Command [2]
Command [2] : 1= Top ; 2 = bring to front ; 3 = send to back
Data
Data [0] = Window type byte
Window type byte value:
0 = Data A ; 1 = Video A ; 2 = Data B ; 3 = Video B
Example
Brings the Data A window to the front
Transmit
Start
Projector address
110
\x26
\x95
\x27
\x95
\x12
\x0e
1,2,3
\xfe
\x01
R5976884 RLM SERIES 04/04/2006