2. Basic Commands
Receive (acknowledge)
Command[0]
Command[1]
Checksum
Stop
Receive (Answer)
Start
Projector address
Command[0]
Command[1]
Data [0]
Checksum
Stop
2.30.3 Lamp Status, Read
Description
Reads the actual Lamp Status of the projector
Command
Command [0]
Command [1]
Returned Data
Data [0] = Lamp Mode = unsigned byte see "Lamp Mode, Read", page 63
Data [1] = Active lamp(s) = unsigned byte (see following table)
Lamp
Lamp1
Lamp2
Lamp1+Lamp2
Table 2-209
Lamp status: active lamps table
Example
Reads the actual Lamp Status of the projector, the awnser being \x01 = Lamp1 (in single mode)
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
64
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x0c
\x00
\x2e
\xff
\x21
\x0d
byte
0001
0010
0011
\xfe
\x01
\x21
\x0d
\x2f
\xff
Hex
\x01
\x02
\x03