Window Size, Increment; Window X Position, Increment; Window Y Position, Increment - Barco RLM series User Manual

Rs232 commands
Table of Contents

Advertisement

3. Advanced Commands
50% corresponds to a zoom window in the middle of the window.
Command
Command [0]
Command [1]
Data
Data [0]...Data [3] = double word(= 4 bytes; see chapter "1. Serial communications Basics", "Data words", page 6) corresponding
to the actual Y position (100% = right border).
Data[4] = unsigned byte : represents the decimal part.

3.12.10 Window size, Increment

Description
This command increments the zoom factor of the active window (window which has the focus).
This is done by incrementing the size percentage, the rate of increment can also be specified.
Command
Command [0]
Command [1]
Data
Data [0] = byRepeat =1 byte to define the rate of increment

3.12.11 Window X position, Increment

Description
This command increments the X position of the zoom window.
This is done by incrementing the X position percentage, the rate of increment can also be specified
Command
Command [0]
Command [1]
Data
Data [0] = byRepeat =1 byte to define the rate of increment

3.12.12 Window Y position, Increment

Description
This command increments the Y position of the zoom window.
This is done by incrementing the Y position percentage, the rate of increment can also be specified
Command
Command [0]
Command [1]
Data
Data [0] = byRepeat =1 byte to define the rate of increment
122
\x21
\x83
\x22
\x81
\x22
\x82
\x22
\x83
R5976884 RLM SERIES 04/04/2006